Quick Reference Guide 5
PRESS
DURATION
FUNCTION COMMENT
Momentary
(when scanner is
asleep)
Wakes scanner from
Sleep Mode
Alternatively, the scanner can
be awakened by:
- Moving an object through the
scan zone.
- Scanning with an attached
auxiliary scanner.
Momentary
(when scanner is
awake)
Increments volume
Press the button momentarily
to increase speaker volume.
When the loudest volume is
reached, a repeated press of
the button cycles volume back
to the lowest setting, then vol-
ume increases on subsequent
press(es). Five volume levels
are available.
Hold, then
release when the
beeper sounds
Increments tone
Press the button for approxi-
mately 2 seconds, then release.
Each time this is done, the
beeper will sound at one of
three tones. Stop when the
desired tone (high, medium or
low) is sounded.
4 Seconds
Scanner Diagnostics
Mode
a
This mode allows system sup-
port personnel to troubleshoot
problems with the scanner and
is used to determine if it can
read bar codes. Press the but-
ton for 8 seconds or cycle
power to exit Scanner Diagnos-
tics Mode and reset the scan-
ner.
8 Seconds Resets Scanner
b
Only system support person-
nel should perform a reset.
a. By standard default, this function is normally disabled to prevent
accidental activation by users.
b. Users should not perform scanner resets except under the direction