Do you have a question about the Datalogic Magellan 3450VSi and is the answer not in the manual?
Standard interfaces | RS-232 |
---|---|
Connectivity technology | Wired |
Type | Fixed bar code reader |
Sensor type | LED |
Scanner type | 1D/2D |
Read rate (max) | 39000000 reads/s |
Yaw reading angle | -75 - 75 ° |
Tilt reading angle | 0 - 360 ° |
Pitch reading angle | -65 - 65 ° |
Light levels (direct sunlight) | 0 - 86000 lx |
Linear (1D) barcodes supported | - |
2D (matrix & stacked) barcodes supported | Aztec Code, Data Matrix, MaxiCode, QR Code |
Input voltage | 100-240 V |
Input frequency | 50-60 Hz |
Power source type | AC |
Power consumption (standby) | 2.6 W |
Power consumption (typical) | 3 W |
Storage temperature (T-T) | -40 - 70 °C |
Operating temperature (T-T) | 0 - 40 °C |
Operating relative humidity (H-H) | 5 - 95 % |
Product color | Black |
International Protection (IP) code | IP52 |
Sustainability certificates | RoHS |
Harmonized System (HS) code | 84716070 |
Depth | 94 mm |
---|---|
Width | 152 mm |
Height | 137 mm |
Weight | 600 g |
Provides overview of manual content, connection, programming, specs, and references.
Explains symbols used for important notes, cautions, and warnings.
Details how to connect the scanner to a terminal or PC via various interfaces.
Explains scanner mounting options including L-bracket, wall, countertop, and riser.
Explains how programming bar codes in the manual customize scanner features.
Suggests reviewing basics for users new to bar code programming.
Details how to use programming bar codes to configure scanner settings.
Restores factory default settings via a bar code scan.
Explains the purpose of a mask for single bar code scanning.
Sets minimum time between consecutive reads of the same 1D label.
Sets minimum time between consecutive reads of the same 2D label.
Contains settings for Digital Watermark decoding, including enable and data format.
Specifies inactivity time before the scanner enters sleep mode.
Toggles inverted label reading for 1D bar codes, e.g., white on black.
Enables or disables the scanner beep upon successful decoding of a label.
Sets the timeout for waiting for a handheld response during host download.
Explains methods for capturing and saving images to microSD or host.
Explains setting up camera button for image capture to POS.
Specifies the destination for pictures/images taken with a camera button press.
Enables/disables mode for mobile phone read, keeping scanner active.
Sets time for subsequent camera button requests after retrieval label.
Specifies the current scanner interface and its identification number.
Details setup for USB-COM interfaces, including driver installation.
Guides selection of RS-232 interface types like Standard, Wincor-Nixdorf, Single Cable.
Guides selection of USB interface types like OEM, TEC, COM.
Specifies maximum characters allowed in messages transmitted to the host.
Sets the data transmission rate for RS-232 communication.
Specifies the parity setting for sending and receiving RS-232 data.
Enables/disables the RS-232 CTS signal for flow and scan control.
Contains settings related to the RS-232 ACK/NAK protocol.
Specifies the ASCII character used as an ACK character for RS-232.
Specifies the ASCII character used as a NAK character for RS-232.
Sets the time scanner waits for ACK after label transmission.
Configures whether the scanner ignores host commands, except for essential ones.
References other RS-232 features shared with single cable interface.
Specifies how RTS/CTS signals control data flow for single cable RS-232.
Enables or disables the use of STX for single cable RS-232.
Enables or disables the use of ETX for single cable RS-232.
Enables sending Pacesetter Plus info as trailers to UPC/EAN bar codes.
Identifies scanner as Table Top or Handheld for OEM-USB protocol.
Configures scanner behavior upon Bus Reset for USB OEM interfaces.
Notes country support; refer to OS manual for details.
Specifies the country/language supported by the keyboard interface.
Specifies character data format regarding Caps Lock state.
Sets time to monitor keyboard activity before breaking connection.
Explains building user-defined data into message strings sent with bar codes.
Allows adding prefixes/suffixes to bar code data for RS-232 interfaces.
Explains AIM label identifiers from a standardized list used for symbology identification.
Provides settings for identifying bar codes with custom or standard labels.
Controls the method of processing coupon labels like UPC-A and GS1 DataBar Expanded.
Enables or disables the scanner's ability to decode UPC-A labels.
Enables or disables the scanner's ability to decode UPC-E labels.
Enables or disables the scanner's ability to decode EAN/JAN-13 labels.
Enables or disables the scanner's ability to decode EAN/JAN-8 labels.
Enables/disables price/weight check digit calculation/verification for UPC-A and EAN/JAN-13.
Enables/Disables conversion of UPC/EAN labels to GTIN 14-character format.
Enables or disables the scanner's ability to decode DataBar Omnidirectional labels.
Enables or disables the scanner's ability to decode DataBar Expanded labels.
Enables or disables the scanner's ability to decode DataBar Expanded labels.
Enables or disables the scanner's ability to decode Code 39 labels.
Enables or disables decoding of Italian Pharmaceutical Code 39 labels.
Enables or disables the scanner's ability to decode Code 128 labels.
Enables or disables the scanner's ability to decode Interleaved 2 of 5 labels.
Enables or disables the scanner's ability to decode Codabar labels.
Enables or disables the scanner's ability to decode Code 93 labels.
Enables or disables the scanner's ability to decode MSI labels.
Enables or disables the scanner's ability to decode Standard 2 of 5 labels.
Enables or disables the scanner's ability to decode Data Matrix labels.
Enables the processing of PDF417 bar code labels.
Enables or disables the scanner's ability to decode Micro PDF 417 labels.
Enables or disables the scanner's ability to decode QR Code labels.
Enables or disables the scanner's ability to decode Micro QR Code labels.
Enables or disables the scanner's ability to decode Aztec labels.
Lists the types of bar codes the scanner can decode.
Details electrical specs: power requirements and consumption.
Specifies environmental operating conditions like ambient light, humidity, and temperature.
Provides the physical dimensions and weight of the scanner.
Lists scanner performance parameters like imager sensor, read rate, and angle.
Covers agency approvals and compliance standards for the product.
Explains scanner LED and beeper indications for functions and errors.
Describes scanner beeper functionality and indications like power-on and good read.
Describes scanner error codes, LED flashes/beeps, and recommended corrective actions.
Details pin assignments for primary interface cables like RS-232 and USB.
Provides bar codes for programming alphanumeric characters and digits.
Lists common factory default settings for various scanner interfaces.