Handheld Data Format Requirements General
332 Magellan™ 3450VSi
Datalogic Handheld Data Format Requirements
The following sections describe label transmission formats that are typically
observed in factory configurations of Datalogic handheld scanners.
GS1 DataBar Omnidirectional
Prefix must be ASCII characters ‘R4’
Check character must be included in label
Application identifier “01” must follow the prefix and preceed the base
label
Label length excluding prefix characters must be 16 characters.
Example: ‘R40101044123456789’
GS1 DataBar Expanded
Prefix must be ASCII characters ‘R4’
Check character must be included in label
UPC-A
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Prefix must be an ASCII character 'A' - total length including prefix must
be 13.
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including prefix must
be 15.
Example: 'A06099201118712'.
UPC-A with 5-Digit Supplemental
Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'A' - total length including prefix must
be 18
Example: 'A06099201118712345'
UPC-E
Number system must be included in label data
Check digit must be included in label data and is assumed to be correct
Prefix must be an ASCII character 'E' - total length including prefix must be
9
Example: 'E09988750'
UPC-E with 2-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be correct.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Magellan 3450VSi and is the answer not in the manual?

Datalogic Magellan 3450VSi Specifications

General IconGeneral
Standard interfacesRS-232
Connectivity technologyWired
TypeFixed bar code reader
Sensor typeLED
Scanner type1D/2D
Read rate (max)39000000 reads/s
Yaw reading angle-75 - 75 °
Tilt reading angle0 - 360 °
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 86000 lx
Linear (1D) barcodes supported-
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, MaxiCode, QR Code
Input voltage100-240 V
Input frequency50-60 Hz
Power source typeAC
Power consumption (standby)2.6 W
Power consumption (typical)3 W
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)5 - 95 %
Product colorBlack
International Protection (IP) codeIP52
Sustainability certificatesRoHS
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth94 mm
Width152 mm
Height137 mm
Weight600 g