MSI Length 2 Enter/Exit Programming Mode
Product Reference Guide
245
MSI Length 2
If MSI Length Control is set to Fixed-Length decoding, this feature specifies MSI
second fixed length. If MSI Length Control is set to Variable-Length decoding,
this feature specifies the maximum label length.
NOTE
When in Fixed Length mode, if Len
gth 2 is set to the value 00
(zero), then only Length 1 will apply.
To set this feature:
1. Scan the ENTER/EXIT Prog
ramming Mode bar code.
2. Scan the bar code, Set MSI Length 2 on page 245 below. You’ll need to
cover any unused bar codes on this and the f
acing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Scan the appropriate digits from the Alpha-Numeric Keypa
d in Appendix C
that represent the desired l
abel length. The selectable range for this
option is 00 (meaning ignore this length), or 04 to 16. Pad all single digit
numbers with a leading zero to yield a two-digit entry (00, 04-16).
4. Complete the programming sequence
by scanning the ENTER/EXIT Pro-
gramming Mode bar code.
00CC(CR)
Set MSI Length 2
DEFAULT
Default setting for this feature = 10