SOFTWARE CONFIGURATION
113
7
For Matrix 120 readers some of these alarms are not relevant. The following table shows the
relevant alarms:
Alarm
Code
Description
Meaning
171
Protocol Index Failure
The expected Protocol Index is not received
189
Fieldbus Communication
Failure
There is a communication error between the scanner and
the Fieldbus module inside the CBX connection box or
QLM Gateway.
191
Fieldbus Type Mismatch
The Fieldbus module inside the CBX doesn't match the one
saved in the scanner configuration memory.
193
Fieldbus Configuration
Error
A configuration error has occurred between the scanner
and the Fieldbus module inside the CBX connection box.
195
Fieldbus DHCP Problem
A communication problem has occurred between the
DHCP server and the Fieldbus module inside the CBX
connection box or QLM Gateway.
999998
Camera Head Failure
The Matrix 120 Camera Head has failed.
7.8 STATISTICS
Statistics on the reading performance can be viewed by enabling the Statistics panel from
the DL.CODE Monitor item selected from the File menu (or Monitor icon).
Figure 69 - Reading Statistics