RAPID CONFIGURATION
5
1
STEP 2 MOUNT AND POSITION THE READER
1. To mount the Matrix 120, use the mounting brackets to obtain the most suitable position
for the reader. A common mounting configuration is shown in the figure below.
Figure 4 Positioning with Mounting Bracket
2. When mounting the Matrix 120 take into consideration these three ideal label position angles:
Pitch or Skew 10° to 20° and Tilt , although the reader can read a code at any tilt angle
provided the code fits into the Field Of View (FOV).
Figure 5 Pitch, Tilt and Skew Angles
3. Refer to the reading diagrams in chp. 6 to determine the distance your reader should be
positioned at.
NOTE: Rapid Configuration of the Matrix 120 reader can be made either
through the X-PRESS interface (step 3) which requires no PC connection,
or by using the DL.CODE Configuration Program (steps 4-5). Select the
procedure according to your needs.
Pitch
Skew
Pitch
Minimize
No Pitch, Tilt
or Skew
Tilt
any angle inside
FOV
Skew
Assure at least 10°
FOV
H
FOV
V