MATRIX 120™ REFERENCE MANUAL
4
1
CBX100/CBX500 Pinout for Matrix 120
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout only when the Matrix 120 reader is connected to the CBX100/CBX500 by means of
the CAB-1011 accessory cable:
CBX100/500 Terminal Block Connectors
Input Power
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference External Trigger
+V
Power Source Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference Inputs
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 + opto-isolated and polarity sensitive
O1-
Output 1 - opto-isolated and polarity sensitive
O2+
Output 2 + opto-isolated and polarity sensitive
O2-
Output 2 - opto-isolated and polarity sensitive
Auxiliary Interface
Matrix 120 has no Auxiliary Interface
ID-NET
Matrix 120 has no ID-NET Interface
Shield
Cable shield connected to chassis and 17-pin connector shell
Main Interface
RS232
RS422 Full-Duplex
TX
TX+
RX
*RX+
-
TX-
-
*RX-
SGND
SGND
* Do not leave floating, see par. 4.2.2 for connection details.
CAUTION: Do not connect GND and SGND to different (external) ground
references. GND and SGND are internally connected through filtering circuitry
which can be permanently damaged if subjected to voltage drops over 0.8
Vdc.