RAPID CONFIGURATION
25
1
STEP 6 TEST MODE
Use a code suitable to your application to test the reading performance of the system.
1. Enter the Test function by pressing and holding the X-PRESS push button until the Test
LED is on.
2. Release the button to enter the Test function.
Once entered, the Bar Graph on the five LEDs is activated and if the reader starts
reading codes the Bar-Graph shows the Good Read Rate.
Figure 13 X-PRESS Interface: Test Function
3. To exit the Test, press the X-PRESS push button once.
NOTE: By default, the Test exits automatically after three minutes.
The Bar Graph has the following meaning:
Figure 14 Test Function Bar Graph
In case of No Read condition, only the STATUS LED (red) is on and blinks.
95 %
75 %
60 %
40 %
20 %