MATRIX 120™ REFERENCE MANUAL
6
1
STEP 3 X-PRESS CONFIGURATION
The Matrix 120 models are factory focused to the 70 mm Reading Distance (WVGA models)
or 80 mm Reading Distance (MP models). If this distance is compatible with your application
you can use the X-PRESS Interface to install the reader, if not, use the DL.CODE procedure
described in step 6 “Image Setup.
Focus/Aiming
Matrix 120 devices provide a built-in aiming system to aid reader positioning. The aiming
system is accessed through the X-PRESS Interface.
1. Power the reader on. During the reader startup (reset or restart phase), all the LEDs blink
for one second. On the connector side of the reader near the cable, the “POWER ON”
LED (blue) indicates the reader is correctly powered.
2. Enter the Focus/Aim function by pressing and holding the X-PRESS push button until the
Aim LED is on.
3. Release the button to enter the Aim function. The aiming system turns on see Figure 6.
4. Place an application specific code in front of the reader at the reading distance
indicated for your model as described above, centering it a few mm to the left of the
aiming system indicator as shown below.
Figure 6 Aiming Function Using The Red Crosshairs
Figure 7 X-PRESS Interface: Aim Function
5. Exit the Aim function by pressing the X-PRESS push button once. The aiming system
turns off.
FOV