MATRIX 120™ REFERENCE MANUAL
5 to 30 Vdc
(10 to 30 Vdc with CBX)
Main
- RS232
- RS422 full-duplex
2400 to 115200 bit/s
2400 to 115200 bit/s
Ethernet (Built-in)
supported application protocols
10/100 Mbit/s
TCP/IP, EtherNet/IP, Modbus TCP, PROFINET-IO
CBX500 with HMS Host Interface Modules
Inputs
Input 1(External Trigger) and Input 2
short circuit protected
(opto-isolated and polarity insensitive when connected through CBX)
3.5 mA (24 mA max when connected through CBX)
NPN or PNP short circuit protected
(opto-isolated and polarity sensitive when connected through CBX)
V
OUT high
(I
LOAD
= -100 mA) Max.
28.3 Vdc (when using 30 Vdc power supply)
V
OUT low
(I
LOAD
= 100 mA) Max.
Focus Range
4
Factory calibrated positions (mm)
CMOS sensor with Global Shutter
0° - 360° (within vertical FOV)
Laser Safety (Aiming source)
0 to 45 C (32 to 113 °F)
-20 to 70 C (-4 to 158 °F)
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 500 Hz; 2 hours on each axis
Protection Class
EN 60529
when connected to the CBX connection boxes the electrical features for Output 1 and 2 become the following:
Opto-isolated; V
CE
= 30 Vdc max.; I
CE
= 40 mA continuous max.; 130 mA pulsed max.;
V
CE saturation
= 1 Vdc max. @ 10 mA; P
D
= 90 mW Max. @ 50 °C ambient temp.
three factory calibrated positions; continuous focus range for fine tuning
high ambient temperature applications should use metal mounting bracket for heat dissipation