TYPICAL LAYOUTS
65
5
The CAB-1051 allows I/O devices to be connected to the reader when using the USB
interface.
Figure 55 USB Point-to-Point Layout with I/O
The electrical connections between I/O devices and CAB-1051, together with the relative
Matrix 120 Line Type parameter settings are shown below.
Inputs
Outputs
V
ext
= 5-30 Vdc max
I
IN
= 3.5 mA max
V
ext
= 5-30 Vdc max
I
CE
= 100 mA max
V
out
= 3.3 Vdc max
I
out
= 50 mA max
CAB-1051
Input 1 (Trigger) = orange
Input 2 = grey
GND = black
CAB-1051
Output 1 = purple
Output 2 = red/white
GND = black
CAB-1051
Matrix 120
Host
5-30 Vdc
External Power only
for I/O Accessories
I/O
I/O