Enter Configuration
Exit and Save Configuration
Ì$+;Î
DATA FORMAT
Ì$-?Î
71
CODE IDENTIFIER
disable
ÌEB0SÎ
Datalogic standard
AIM standard
ÌEB1VÎ
ÌEB2YÎ
custom
ÌEB3\Î
CUSTOM CODE IDENTIFIER
define custom code identifier(s)
ÌEH/Î
Read the above code.
(Code Identifiers default to Datalogic standard, see table on previous page).
Select the code type from the code table in Appendix
B for the identifier you want to
change.
You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is
required, the second character must be selected as FF (disabled). Read the hexadecimal
value corresponding to the character(s) you want to define as identifiers for the code
selected in step : valid characters are in the range 00-FD.
Example
: To define Code 39 Code Identifier = @
define custom code identifier(s)
Code 39
Read
ÌEH/Î
+
ÌVWÎ
+
40
+
FF

Table of Contents