EasyManuals Logo

Datalogic QuickScan QD2430 User Manual

Datalogic QuickScan QD2430
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #34 background imageLoading...
Page #34 background image
Error Codes
26 QuickScan™ QD2430
Error Codes
Upon startup, if the reader sounds a long tone, this means the
reader has not passed its automatic Selftest and has entered
FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. Press and release the
trigger to hear the FRU indication code.
The following table describes the LED flashes/beep codes
associated with an error found.
Number
of LED
Flashes/
Beeps
Error Corrective Action
1 Configuration
Contact Helpdesk for assis-
tance
2Interface PCB
6 Digital PCB
11 Imager

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QD2430 and is the answer not in the manual?

Datalogic QuickScan QD2430 Specifications

General IconGeneral
Scanner Type2D Area Imager
IP RatingIP42
Print Contrast Ratio (Minimum)25%
Motion Tolerance25 IPS
Ambient Light0 - 100, 000 lux
ESD Protection (Air Discharge)16 kV
Operating Temperature0 to 50 °C / 32 to 122 °F
Storage Temperature-40 to 70 °C / -40 to 158 °F
Humidity (Non-Condensing)5 - 95%
Light SourceRed LED
Resolution0.1 mm (4 mil)
InterfaceUSB, RS-232, Keyboard Wedge
Drop ResistanceWithstands drops from 1.5 m / 5.0 ft
Weight145.0 g / 5.1 oz
Image Sensor752 x 480 pixels
Decode Capability1D / Linear Codes, Stacked Codes, 2D Codes, Postal Codes
Reading AnglePitch: +/- 65°, Roll: 360°, Skew: +/- 60°
Power Supply5 VDC +/- 5%

Related product manuals