M-Class 59
Communications (continued)
SPEED COMMANDS
Allows the user to disable the DPL speed commands (Print, Feed, Slew, and
Reverse).
ENABLED
Normal printer operating mode.
DISABLED
DPL speed commands are ignored. The speeds are controlled via the menu setting;
see Section 5.1.3.
TOF SENSING COMMANDS
Allows the user to disable the DPL Top of Form commands (Gap, Continuous, and
Reflective).
ENABLED
Normal printer operating mode.
DISABLED
DPL TOF commands are ignored. The TOF is controlled via the menu setting; see
Section 5.1.2.
SYMBOL SET COMMAND
Allows the user to disable the DPL Single and Double Symbol Set selection
commands.
ENABLED
Normal printer operating mode.
DISABLED
DPL Symbol Set commands are ignored. The Symbol Set selection is controlled
via the menu setting; see Section 5.1.5.
CNTRL-CODES (DATA)
Allows the user to remove control codes (data < 20 Hex) from the data fields. The
selected line terminator is processed.
ENABLED
Normal printer operating mode.
DISABLED
DPL Control Code (SOH, STX, CR, ESC, and ^) functions are ignored.
STX-V SW SETTINGS
Allows the user to disable DPL software switch settings commands.
ENABLED
Normal printer operating mode.
DISABLED
DPL option-enable command (<STX>V) is ignored.