DP-50 / DP-50D / MP55-B - USERS MANUAL
OPERATION MODES
The ECRs working mode can be set when on the display is shown
O F F
by pressing the key:
1
REG - 'REGISTRATION', Registering of the sales;
2
X - 'X REPORTS', Reports of the ECR;
3
Z - 'Z REPORTS', Reports of the ECR with clearing;
4
PGM - 'PROGRAMMING', Programming of the ECR settings;
7
- Connection to PC for:
1. Reporting the fiscal memory (by using the applications
'Memory Reader' and 'Fiscal Memory Interpreter' or other with
similar functionality);
8
- Control tests ;
9
- Programming and reporting from PC
( by using the application "Ecr Tool" or its analog)
.
- Showing the battery voltage and the current date and time.
0
- Turning off the ECR when it is in "OFF" mode.
From any state of the ECR with the keys
<>
/
OFF
the current state changes to
O F F
The operators have no equal rights when accessing the modes. The access
permissions are defined as the follows:
- operators 1..24 (cashiers) are allowed to access only REG mode;
- operators 25, 26 are allowed to access REG and Х modes;
- operators 27, 28 are allowed to access REG, Х and Z modes;