Message
Solution
Message
Solution
Message
Solution
Message
Solution
Message
Solution
6.1.27 Message: Temp. sensor disconnected
Temp. sensor disconnected
Consult the service engineer (see Service and support on page
3).
6.1.28 Message: Temperature boiler (too) high
Temperature boiler (too) high
1. Open the door of the coffee machine.
2.
Insert the service key.
3.
Perform the procedure Flush mixers and brewer (on page 50)
several times.
4.
If message is still shown: Consult the service engineer (see
Service and support on page 3).
6.1.29 Message: Water level too low
Water level too low
Consult the service engineer (see Service and support on page
3).
6.1.30 Message: Wait, Heating boiler
Wait, Heating boiler
Perform the following steps to solve the problem:
1. Wait until boiler is heated.
2. If message is still shown after 10 minutes: Consult the service
engineer (see Service and support on page 3).
6.1.31 Message: Waste bucket full / Empty waste bucket
Waste bucket full / Empty waste bucket
Perform the following steps to solve the problem:
1. Empty waste bucket (see Clean waste bucket on page 51).
▪ If message is still shown, remove the waste bucket and
wait 6 seconds before placing it back.
101
Virtu CEC Medium Cabinet 70/90 CoEx® brewer User Manual 5DUCEK20M EN V2.1