D E H L E R 3 4
In case of fire in the other areas
Try to extinguish the fire with the fire blanket or with water if no inflammable liquids are involved.
Otherwise, use the fire extinguisher to fight the fire. Use the rescue belt to facilitate the exit via the
escape hatch in case of emergency. The escape rescue belt is only to be used in case of
emergency, since its use can damage the surface quality of the hatch frame.
The stowage for the rescue belt may not be altered! Free access is
to be guaranteed at all times!
Safety notes regarding the operation of the liquefied petroleum gas (LPG) unit
The yacht is equipped with an LPG unit. Please observe the following notes when operating it.
If a leak is detected shut off the main LPG supply valve and do not
use LPG appliances.
Action in case of a smell of gas
If you smell gas, shut the valve of the gas cylinder and ventilate the boat intensively. The
presence of gas fumes can be checked for by means of gas detectors.
Have a specialist examine and remedy the cause before using the gas system again!
Notes on preventing malfunctions of the LPG unit:
• LPG supply line valves and cylinder valves shall be closed when appliances are not in use,
before refuelling and immediately in an emergency.
• Make sure that the valves of the appliances are shut before opening the valve of the cylinder!
• Check the LPG unit for possible leakages before each use:
Shut the valves of the appliance; open the valve of the cylinder; wait for stabilisation
from the pressure; shut the valve of the cylinder; watch on the manometer for
3 minutes; the pressure should remain constant!
If pressure gauge reading falls, leak is present: do not use LPG appliances!
Do not use an installation that has leaked until it has been
inspected and repaired by a competent person.
• Manual leak testing with foam-producing, soapy water or detergent solutions (with appliance
burner valves closed and cylinder and system valves open); foam-producing solutions for leak
detection on gas installations in accordance with EN 14291 meet these requirements;
• If there are leakages, shut the valve of the cylinder and have the system repaired by a specialist
before using the appliance again.