No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
The tubes in the peristaltic pumps should
be replaced at least two times a year.
The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
ð
The large button indicator light has a
the top segment is solid red and the
other segments flash slowly in white
until the milk flow is above the low flow
limit.
When the milk flow is above the low
flow limit, the large button indicator light
turns into a solid white and the top seg-
ment is solid red.
When the flow is below the take-off
limit, the large button indicator light is
flashing rapidly white and the top seg-
ment is solid red until the cluster is
retracted.
The large button indicator light turns to
solid green at normal take-off. The top
segment is solid red still indicating the
override.
If the large button indicator light is flash-
ing rapidly yellow, the milk yield is
below the expected level. The top seg-
ment is solid red still indicating the
override. Check if a reattach is needed,
see
Ä
Chapter 4.4 "Reattaching a clus-
ter" on page 45.
If the large button indicator light,
despite flashing rate, turns to yellow, it
means that a milking alarm has been
detected. The top segment is solid red
still indicating the override. Check if a
reattach is needed, see
Ä
Chapter 4.4 "Reattaching a clus-
ter" on page 45.
DeLaval milking automation MA200 (Test installation)
Operation
© DeLaval 2019.
2019-05-31, Version 1 43 (62)