No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
The tubes in the peristaltic pumps should
be replaced at least two times a year.
The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
6 Safety devices
This system is designed to be safe to operate.
The safety devices that are installed are there for
personal safety and must not be modified,
removed, or disconnected.
Any modification to the equipment's original
design may compromise the personal safety.
Consequently it may also void or limit the war-
ranty.
Note! All safety devices in the system must be
checked by a DeLaval representative before the
system is signed over to the customer.
7 Safe and healthy work routines
n Ensure that the area is well lit.
n Keep the floor dry to avoid slipping.
n Wear protective clothing and appropriate
shoes or boots.
n Keep a good milking hygiene.