No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
• The tubes in the peristaltic pumps should
be replaced at least two times a year.
• The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
Troubleshooting
DeLaval milking automation
MA200 (Test installation)
1 Procedure when a problem
occurs
1. Make a note in an error log file on the desk-
top of the DelPro computer describing the
error.
Note the following:
n Date (YYYY-MM-DD) and time
(HH:MM) when the problem occurred
n What happened (the actual symptoms
of the problem)?
n Is the problem reoccurring at a milking
point?
n Is the problem with one button module
or with several / all?
Example; 2019-05-26 at 08:36 AM: Cow no
126 premature take-off at milking point 3.
Note! This is very important for support
personnel who are not present first hand
when the problem occurred.
2. If no alarm code is present, look through
the "Possible problems" section, see .
3. If it is necessary to contact a service tech-
nician, make sure as much detailed infor-
mation as possible is available on the
installation, such as:
n Software version (and possibly serial
number) of the button module
n Flow sensor type
n Number of button modules connected
to each smart connection box
n Serial number of the smart control box
2 Possible problems
The tables below describe possible problems
with the system, what might cause the problem,
and suggestions on how the problem might be
solved.
DeLaval milking automation MA200 (Test installation)
Troubleshooting
© DeLaval 2019.