Preliminary
941322_VMS Instruction Book 2006.pdf2009-09-07
No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
• The tubes in the peristaltic pumps should
be replaced at least two times a year.
• The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
1.3 Herd management alarms
Herd Management alarms are pre-set according
to special conditions of the animal.
Note! To set a herd management alarm to an
animal, see DelPro software.
Note! The indications of the herd management
alarms are shown only by the large button indi-
cator.
Status Indication Description Possible actions
Do not Milk
(Large button is
blocked)
The large button indicator
is solid red
This animal is not eligible to
milk extraction.
Press:
N/A
Press and hold:
Override, refer to
Ä
Chapter 1.5 "Over-
ride" on page 20.
Dump milk
(Large button is
blocked)
The large button indicator
is rapid flashing red.
The milk of this animal is not
eligible to be mixed with the
milk for general collection.
Note! Consider milking in a
bucket, refer to linktarget doesn't
exist but @y.link.required='true'.
1.4 Milking alarms
Note! On rotaries using retention bars, when a
milking alarm is detected, the retention bar can
be lowered immediately on detection or at the
confirmed point according to farm settings. See
Ä
Chapter 1.9.3 "Additional rota-
tion" on page 25.
Note! Cluster take-off can be implemented
immediately on detection of a milking alarm
according to farm settings, unless if manual milk-
ing is active.
DeLaval milking automation MA200 (Test installation)
Quick guide
© DeLaval 2019.
2019-05-31, Version 1 16 (62)