941322_VMS Instruction Book 2006.pdf2009-09-07
No. Name Range Default Description/optionsNo. Name Range Default Description/options
0 = no acidic cleaning0 = no acidic cleaning
1 = one alkaline, one acidic cleaning1 = one alkaline, one acidic cleaning
2 = two alkaline, one acidic cleaning2 = two alkaline, one acidic cleaning
3 = etc.3 = etc.
Maintenance an calibration
The following points are important to sustain
correct dosing of etergents. Note that
these two tasks should be performed by an
authorised DeLaval service engineer.
• The tubes in the peristaltic pumps should
be replaced at least two times a year.
• The dosing volume (P6-P8) of the
detergent pumps should be checked
every third month. The dosing capacity
(P32-P34) may need to be adjusted.
Starting cleaning or rinsing
from the touch screen
Note: Any ongoing backflush process must
first be finished before cleaning or rinsing
can be started.
1. Ensure that the milking station is in
manual mode.
2. Remove any cow that might be in the
milking station.
After treatment window
Note: Both gates should be closed to
prevent a cow from entering before the
system cleaning has been started. Closing
and opening gates is done in the Stall
control window.
3. Press the tab After Treatment on the
touch screen to display the After treatment
window.
4. In the After treatment window, press the
Cleaning and Rinsing button. This will open
the Cleaning and rinsing window.
Danger!
Risk of electric shock
Do not spray or flush water on elec-
trical components even when they
are switched off or disconnected.
Water on electrical components can
cause an electric shock, and could
destroy the equipment.
4. Clean the surfaces of the button module
using a sponge and soapy water.
5. Clean the front cover using a sponge and
soapy water. Rinse with water.
Note! Directing the water jet towards the
connections may short circuit the system.
6. Clean the button frame in a dishwasher or
by hand. Rinse with water.
7. Check that all dirt, dust and residues are
removed.
8. Check that the four screws on the button
module unit are correctly fastened and that
there are no gaps in the frame sealing.
Warning!
If the equipment is not properly fas-
tened, it can move and pull the elec-
trical cables loose. This may cause
personal injury and risk of fire.
9. Reinstall the buttons onto the button frame.
Checking the parts
Reassembling the front cover and button
frame
DeLaval milking automation MA200 (Test installation)
Operator's maintenance
© DeLaval 2019.
2019-05-31, Version 1 52 (62)