V0413, 12
Depending on the machine specifications one or more of the
below mentioned functions can be available on the program
constants screen.
Retract time: The moment of X-axis
retract is delayed by the value pro-
grammed for this parameter. The
value is programmed in seconds.
Bending time: The function of this
parameters is depending on the
machine design. Please contact the
machine documentation or contact
the machine supplier for the function
of this timer.
Decompresion time: The function of
this parameters is depending on the
machine design. Please contact the
machine documentation or contact
the machine supplier for the function
of this timer.
Current X-axis position. Program the
current position of the X-axis. The
control will retain this position value
after power-down and automatically
assume the same position value after
power-on. After power-on, verify the
axis position and correct this param-
eter when necessary.This parameter
is only available in case there is no
reference system for this axis
installed on the machine.
X-axis correction.With this parameter
the correct position can be (re)cali-
brated.
Current Y-axis position. This parame-
ter works the same as for the X-axis.