V1204, 2.19
Parameter 27:
Brake delay
Range : 0.0 - 0.99
Unit : seconds
Default : 0.00
Function
Delay time before AC brake is activated.
Parameter 28:
Breakpoint Fast Speed BFS
Range : 0.0 - 9999.9
Unit : mm
Default : 10.0
Function
Switch point from high speed to slow speed.
Parameter 29:
Breakpoint Slow Speed BSS
Range : 0.0 - 9999.9
Unit : mm
Default : 1.0
Function
Switch point from low speed to zero.
Parameter 30:
Stop time T
Range : 0 - 9.99
Unit : -
Default : 0.0.
Function
Delay time before switching off low speed after BSS has been reached