Parameter 31:
Overrun
Range : 0.0 - 9999.9
Unit : mm
Default : 1.0
Function
Overrun distance in case of one side positioning. One-side positioning is chosen with
parameter 11, ‘spindle allowance’.
An overrun is also done when an AC-drive must change position over a small distance,
smaller than BSS. If such a situation occurs, the axis is first moved to the overrun position and
then back to the required position. The overrun should not be programmed smaller than BSS.
In case it is, the BSS is used as overrun.
See also section 2.3 about drive types.
Parameter 32:
Overrun wait time
Range : 0.0 - 9.9
Unit : seconds
Default : 1.0
Function
Wait time at overrun position before the backgauge starts positioning in the opposite
direction.
Parameter 33:
DC Slow speed
Range : 1 - 100
Unit : %
Default : 4
Function
This parameter must be programmed if 2-speed DC motor drives are used. It is programmed
as a percentage of maximum output deflection (10 V)
Parameter 34:
DC fast speed
Range : 1 - 100
Unit : %
Default : 80
Function
This parameter must be programmed if 2-speed DC motor drives are used. It is progammed as
a percentage of maximum output deflection (10 V)