Parameter 46:
Reference search speed
Range : 1 - 100
Unit : %
Default : 50
Function
Axis speed during reference searching.
Parameter 50:
Stroke mode
Range : 0 - 2
Unit : -
Default : 0
Function
When the stroke option is enabled, the user can program the desired stroke length as a
percentage (0-100%) of the maximum stroke length. This percentage value can be
programmed in every step by the S parameter. When the programmed stroke length is
reached, the ‘EOS’ output will become high.
0 = No stroke option (‘S’ disabled in user interface)
1 = Stroke length using timer
2 = Stroke length using analog feedback (using input ‘SFB’)
In case of 1and 2, the following I/O is used:
digital output EOS
analog input SFB (only system 2)