Parameter 51:
Stroke time
Range : 0 - 999.9
Unit : seconds
Default : 0
Function
With this parameter, it is possible to set a maximum stroke length in seconds. When that
programmed time has elapsed, the output EOS will become active. This is only used when the
parameter ‘stroke mode’ is set to 1.
The user can program the desired stroke length as a percentage (0-100%) of the maximum
machine parameter time. This percentage value can be programmed in every step by the S
parameter.
When the percentage value is programmed zero then the stroke limitation is not active in that
step.
In this case the EOS output will not be activated.
Note: When the DAC-310 is stopped, the EOS output will be off.
Parameter 52:
Stroke AD min
Range : 0 - 255
Unit : AD value
Default : 0
Function
The AD value corresponding with a 0% stroke. Only valid when stroke option with analog
feedback selected (stroke mode = 2).
Parameter 53:
Stroke AD max
Range : 0 - 255
Unit : AD value
Default : 0
Function
The AD value corresponding with a 100% stroke. Only valid when stroke option with analog
feedback selected (stroke mode = 2).