V1204, 2.25
Parameter 55:
Angle control
Range : 0 - 1
Unit : -
Default : 0
Function
Switch Angle control ON or OFF.
0 = No angle control
1 = Angle control
In case of angle control, the following I/O is used:
digital outputs A+ and A-
analog input AFB.
Parameter 56:
Minimum angle
Range : 0.0 - 45.0
Unit : °
Default : 0.0
Function
The minimum possible shear angle. Only valid when angle control is enabled.
Parameter 57:
Maximum angle
Range : 0.0 - 45.0
Unit : °
Default : 25.5
Function
The maximum possible angle. Only valid when angle control is enabled.
Parameter 58:
Angle AD min
Range : 0 - 255
Unit : AD value
Default : 0
Function
The AD value corresponding with the minimum angle. Only valid when angle option enabled.