EasyManua.ls Logo

Dell EMC DLm8500 Data Domain - Network Software Ports for DLm Disaster Recovery Testing

Dell EMC DLm8500 Data Domain
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 2 Required Network Ports for DLm Operations (continued)
Port
Number
Port Type Protocol(s
)
Traffic User Direction of
Traffic
Notes
636 TCP/UDP LDAP Secure LDAP Inbound/
Outbound
N/A
5432 TCP/UDP LDAP PostgreSQL
Database
Inbound/
Outbound
N/A
9443 TCP TCP GUI/
Communicatio
n
Outbound To SRS
Network software ports needed to support DLm Disaster
Recovery Testing
This section describes about requirement of network software ports to support DLm
disaster recovery testing.
To perform DLm Disaster Recovery testing on a mainframe and to allow the mainframe
to write data to the back-end storage, you must configure your firewall to allow traffic
on particular network ports that are different for each back-end storage system type.
The following table lists the special port for Disaster Recovery testing for the various
DLm models:
Table 3
Required Network Port for Disaster Recovery Testing
DLm
Model
Port Number Port Type Traffic
User
Direction
of Traffic
Notes
DLm8500
with
PowerMax
9050 TCP DLMDRD/D
Lm disaster
recovery
Outbound DR to
maintain
DLm8500
with Data
Domain
9060 TCP DLMAUT Inbound/
Outbound
DR to
maintain
DLm8500
with Data
Domain
2051 TCP Replication Inbound/
Outbound
Proprietary
protocol
Installation information
This section contains all the installation-related information.
Discuss and obtain the following site profile information from the Dell EMC Sales
Representative.
The following table lists the external dependencies that need to be considered for
configuring DLm systems.
Configuration and host connectivity
Disk Library for mainframe Physical Planning Guide for DLm8500 17

Table of Contents

Related product manuals