Number Severity Description/Recommended actions
Resolved A SES alert for a current sensor in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
558 Error An Enclosure Management Processor (EMP) reported an alert condition on a fan control module.
A fan module in the enclosure has failed.
Recommended actions:
Replace the fan module.
Warning An Enclosure Management Processor (EMP) reported an alert condition on a fan control module.
The hot swap circuit in the indicated fan module has failed. The fan will continue to operate. However, it is
unsafe to remove this FRU while the enclosure is powered up.
Recommended actions:
-Check that the indicated fan control module is in the indicated enclosure.
If the fan control module is not in the enclosure, install a fan control module FRU immediately.
If the fan control module is in the enclosure, ensure that the fan control module is fully seated in its slot
and that its latch is locked. If the fan control module is fully seated and the Fault/Service Required LEDs
for the fan control module and for the enclosure are on, replace the fan control module FRU immediately.
If that does not resolve the problem, replace the chassis FRU immediately.
When the problem is resolved, an event with the same code will be logged with Resolved severity.
Resolved An Enclosure Management Processor (EMP) reported an alert condition on a fan control module.
A SES alert for a fan module in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
559 Error An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
A drawer motion sensor has detected an excessive level of acceleration or deceleration.
Recommended actions:
To prevent physical damage to drawer components and drives, avoid using excessive force when
removing or inserting drawers.
Warning An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
A drawer motion sensor has detected an excessive level of acceleration or deceleration.
Recommended actions:
To prevent physical damage to drawer components and drives, avoid using excessive force when
removing or inserting drawers.
Resolved An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
A SES alert for a motion sensor in the indicated enclosure has been resolved.
Recommended actions:
No action is required.
560 Critical An Enclosure Management Processor (EMP) reported an alert condition on a motion sensor.
The enclosure management processor is unable to communicate with the fan management device on the
enclosure midplane. This is likely a problem with the midplane.
Recommended actions:
For the indicated enclosure, inspect the status of the fan control modules in system health. If there is a
failure due to the fan management device, both fan control modules should also report a communication
failure (event 558 with Error severity). If system temperatures steadily climb, if possible shut down the
122 Events and event messages