Number Severity Description/Recommended actions
Verify the configured parameters and ask the recipients to confirm that they received the message.
612 Info. An alert condition was detected on an internal chassis SAS connector.
The event message specifies the location of the internal SAS connector in the chassis.
Recommended actions:
No action is required.
613 Error An alert condition was detected on an IOM.
Recommended actions:
Either install the indicated IOM or attempt to reseat it.
If the problem persists, replace the IOM.
Warning An alert condition was detected on an IOM.
Recommended actions:
If uninstalled, install the indicated IOM otherwise attempt to reseat it.
If the problem persists, replace the IOM.
Info. An IOM was uninstalled.
Recommended actions:
No action is required.
Resolved A previous Warning or Error condition for the IOM has been resolved.
Recommended actions:
No action is required.
615 Info. A rebalance operation for an ADAPT disk group has started.
Recommended actions:
No action is required.
616 Warning A rebalance operation for an ADAPT disk group has completed partially (because of drive failure).
Recommended actions:
No action is required.
Info. A rebalance operation for an ADAPT disk group has completed.
Recommended actions:
No action is required.
617 Warning The spare capacity goal is not met.
This event indicates that the available space in the system is insufficient to provide the level of full fault
tolerance that is specified by the target spare capacity. Spare capacity availability can be influenced by
operations that require available space in the system, such as reconstructing data from a failed disk.
Recommended actions:
Add disks to the disk group, or replace any disks that may have failed. The system will automatically
increase the spare capacity to meet the requirements placed on the system by the target spare capacity.
618 Resolved The spare capacity goal is met.
Recommended actions:
No action is required.
619 Error Disk access will change depending on the port used to connect to the expander.
Recommended actions:
132 Events and event messages