Error Code Message Information
Details System performance may be degraded, PCI device may fail to operate, or system may fail
to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1320
Message A bus fatal error was detected on a component at bus <bus>device<device>function
<func>.
LCD Message Bus fatal error on bus <bus> device <device> function <func>. Power cycle system.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1342
Message A bus time-out was detected on a component at slot <number>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1348
Message A PCI parity error was detected on a component at slot <number>.
LCD Message PCI parity error on slot <number>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PCI1360
Message A bus fatal error was detected on a component at slot <number>.
LCD Message Bus fatal error on slot <number>. Re-seat PCI card.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable, reinstall the device.
PDR0001
Message Fault detected on drive <number>.
LCD Message Fault detected on drive <number>. Check drive.
Details The controller detected a failure on the disk and has taken the disk oine.
Action Remove and re-seat the failed disk. If the issue persists, see Getting Help.
PDR1016
Message Drive <number> is removed from disk drive bay <bay>.
LCD Message Drive <number> removed from disk drive bay <bay>. Check drive.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue persists, see Getting Help.
PST0128
Message No memory is detected.
LCD Message No memory is detected. Inspect memory devices.
Details System BIOS was unable to detect memory in the system.
System messages 123