Error Code Message Information
Details The chassis is open. System performance may be degraded, and security may be
compromised.
Action Close the chassis. Check system logs.
SEC0033
Message The chassis is open while the power is o.
LCD Message Intrusion detected. Check chassis cover.
Details The chassis was opened while the power was o. System security may have been
compromised.
Action Close the chassis and verify hardware inventory. Check system logs.
SEL0006
Message All event logging is disabled.
Details This message is displayed when all event logging has been disabled by the user.
Action If unintended, re-enable logging.
SEL0008
Message Log is full.
Details When the event log is full, additional events are not written to the log. Older events may
be overwritten and lost. This message may also appear if the user disabled event logging.
Action Backup and clear log.
SEL0012
Message Could not create or initialize the system event log.
Details If the system event log fails to initialize, platform status and failure events are not
captured. Some management software do not report platform exceptions.
Action Reboot the management controller or iDRAC. Cycle system input power. If problem
persists call support.
SEL1204
Message An unknown system hardware failure detected.
LCD Message Unknown system hardware failure.
Details If the system event log failed to initialize, platform status and failure events are not
captured. Some management software do not report platform exceptions.
Action Re-congure system to the minimum supported conguration. If issues persists, contact
support.
TMP0118
Message The system inlet temperature is less than the lower warning threshold.
LCD Message System inlet temperature is outside of range.
Details Ambient air temperature is too cool.
Action Check the system operating environment.
TMP0119
Message The system inlet temperature is less than the lower critical threshold.
LCD Message System inlet temperature is outside of range.
128 System messages