PowerConnect 5324 Release Notes
System Firmware Version 2.0.0.39 Subject to Change Without Notice Page 12
unlearned source. This is the default
value.
♦ Shutdown — Discards the packet from
any unlearned source and locks the
port. Ports remain locked until they are
activated, or the device is reset.
♦ Discard Shutdown — Discards the
packet from any unlearned source and
locks the port. Ports remain locked until
they are activated, or the device is
reset.
Port Security
In the introduction, under the “Unauthorized packets arriving to a locked port are either:
• Forwarded
• Discarded with no trap
• Discarded with a trap
• The ingress port is disabled”
Note: In order to enable port security, the Multiple Hosts feature must first be enabled on the required port(s).
Port Configuration
Before the CLI example, enter the following Note:
Note: When device wakes up with autobaud enabled, press "Enter" twice to activate the autobaud.
Radius Settings
Modify
Field Current New
Syntax
Parameters
Usage Type — Specifies the server usage
type. Can be one of the following values:
login, 802.1x or all. If unspecified, defaults
to all
Usage Type — Specifies the server usage
type. Can be one of the following values:
login, dot.1x or all. If unspecified, defaults
to all
Description Remote Authorization Dial-In User Service
(RADIUS) servers provide additional
security for networks.
Remote Authorization Dial-In User Service
(RADIUS) servers provide additional
security for networks. Up to 4 RADIUS
servers can be defined.
802.1x
Title Description
Radius attributes relevant to 802.1x
The Radius attributes that are relevant to 802.1x functionality are:
EAPMessage = 79, MessageAuthenticator = 80, State = 24, Class = 25.