System Firmware Version 2.0.0.39 Subject to Change Without Notice Page 18
remove vlan-list—List of VLAN IDs to
remove. Separate non consecutive
VLAN IDs with a comma and no
spaces. A hyphen designate a range
of IDs.
adds all configured VLAN IDs.
remove vlan-list—List of VLAN IDs to
remove. Separate non consecutive VLAN
IDs with a comma and no spaces. A hyphen
designate a range of IDs. The option all
removes all configured VLAN IDs.
crypto certificate generate
Update the command as follows:
Field Current Guide Change to:
Syntax
Parameter
crypto certificate [number] generate [key-
generate [length]] [passphrase string] [cn
common- name] [ou organization-unit] [o
organization] [l location] [st state] [c
country] [duration days]
crypto certificate [number] generate [key-
generate [length]] [cn common- name] [ou
organization-unit] [o organization] [l location] [st
state] [c country] [duration days]
Syntax
Parameter
passphrase string—Passphrase that is
used for exporting the certificate in
PKCS12 file format. If unspecified the
certificate is not exportable. (Range: 8 -
96)
Delete the parameter
sntp broadcast client enable
Change a parameter description:
Current Guide Change to:
User
Guideline
Use the sntp client enable Interface
Configuration mode command to enable the
SNTP client on a specific interface.
Use the sntp broadcast client enable
Interface Configuration mode command to
enable the SNTP client on a specific
interface.
permit (management)
Change a parameter description:
Current Guide Change to:
User
Guideline
The system supports up to 256 management
access rules.
The system supports up to 128
management access rules.

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2