PowerConnect 5324 Release Notes
System Firmware Version 2.0.0.39 Subject to Change Without Notice Page 17
channel-group
Update the command as follows:
Field Current Guide Change to:
User
Guidelines
There are no user guidelines for this
command.
For redundancy reasons, the LACP port channel
can accept up to 16 ports but only 8 will be active
at the same time.
wrr-queue bandwidth
Update the command as follows:
Field Current Guide Change to:
User
Guidelines
All 4 queues are participating
excluding the queues that are
assigned as expedite queues. The
weights of these queues are ignored
in the ratio calculation.
All 4 queues participate in the WRR
exclude the expedite queues, in
which case the corresponded weight
is ignored (not used in the ratio
calculation). The expedite queue is a
priority queue, and it is serviced until
empty before the other queues are
serviced.
All 4 queues are participating excluding the
queues that are assigned as Strict Priority
(SP) queues. The weights of these queues
are ignored in the ratio calculation.
All 4 queues participate in the WRR exclude
the Strict Priority (SP) queues, in which case
the corresponded weight is ignored (not
used in the ratio calculation). The expedite
queue is a priority queue, and it is serviced
until empty before the other queues are
serviced.
rmon collection history
Update the command as follows:
Field Current Guide Change to:
Syntax
Parameter
owner ownername—Records the RMON
statistics group owner name. If
unspecified, the name is an empty string.
owner ownername—Records the RMON
statistics group owner name. If unspecified, the
name is an empty string (Range: 0-20
characters).
switchport trunk allowed vlan
Update the command as follows:
Field Current Guide Change to:
Syntax
Parameter
switchport trunk allowed vlan {add
vlan-list | remove vlan-list }
add vlan-list—List of VLAN IDs to
add. Separate non consecutive VLAN
IDs with a comma and no spaces. A
hyphen designates a range of IDs.
switchport trunk allowed vlan {add vlan-list/all
| remove vlan-list/all }
add vlan-list—List of VLAN IDs to add.
Separate non consecutive VLAN IDs with a
comma and no spaces. A hyphen
designates a range of IDs. The option all

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)