EasyManua.ls Logo

Dell PowerConnect 5324 - Modified Commands in the CLI Reference Guide; Clock Summer-Time; Sntp Anycast Client Enable; Sntp Client Enable

Dell PowerConnect 5324
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerConnect 5324 Release Notes
System Firmware Version 2.0.0.39 Subject to Change Without Notice Page 13
Modified Commands in the CLI Reference Guide
clock summer-time
Under User Guidelines add the following:
The following steps must be completed before setting the summer clock:
3. Summer time configuration, for example: console(config)# clock summer-time recurring usa
4. Define Timezone, for example : console(config)# clock timezone 2 zone RADL
5. Set clock, for example: console# clock set 10:00:00 apr 15 2004
sntp anycast client enable
Update the command as follows:
Field Current Guide Change to:
Description The sntp anycast client enable Global
Configuration mode command enables
anycast client. To disable the polling for
SNTP broadcast client, use the no form of
this command.
The sntp anycast client enable Global
Configuration mode command enables anycast
client. To disable the SNTP anycast client, use
the no form of this command.
sntp client enable
Update the command as follows:
Field Current Guide Change to:
User
Guidelines
Use the sntp client enable Global
Configuration mode command to
enable broadcast clients globally.
Use the sntp broadcast client enable
Global Configuration mode command to
enable broadcast clients globally.
bridge address
Update the command as follows:
Field Current Guide Change to:
Syntax bridge address mac-address {ethernet
interface | port-channel port-channel-
number} [permanent | delete-on-reset |
delete-on-timeout | secure]
bridge address mac-address [permanent |
delete-on-reset | delete-on-timeout | secure]
{ethernet interface | port-channel port-channel-
number}
bridge aging time
Update the command as follows:
Field Current Guide Change to:
Syntax
parameter
seconds — Time is number of seconds.
(Range: 10 - 630 seconds)
seconds — Time is number of seconds. (Range:
10 - 360 seconds)

Other manuals for Dell PowerConnect 5324

Related product manuals