Table 15. Memory specifications
DIMM type DIMM rank
DIMM
ca
pacity
Single processor Dual processors
Minimum
system
capacity
Maximum system
capacity
Minimum
system
capacity
Maximum system
capacity
DDR5 RDIMM
Single rank 16 GB 16 GB 128 GB 32 GB 256 GB
Dual rank
32 GB 32 GB 256 GB 64 GB 512 GB
64 GB 64 GB 512 GB 128 GB 1 TB
Table 16. Memory module sockets
Memory module sockets Speed
16, 288-pin 4800 MT/s
NOTE: Memory DIMM slots are not hot pluggable.
Storage controller specifications
The PowerEdge T560 system supports the following controller cards:
Table 17. Storage controller cards
Supported storage controller cards
Internal controllers
● H
B
A355i fPERC
● H355 fPERC
● H755 fPERC
● H755N fPERC
● H965i fPERC
External controllers
● H
B
A355e
Internal Boot
● Bo
ot Optimized Storage Subsystem (BOSS-N1): HWRAID 0/1 (2x M.2 NVMe SSDs)
Software RAID
● S1
60
SAS Hot Bus Adapters (HBA)
● 22
.5 Gbps SAS Ext. HBA
Drives
Th
e PowerEdge T560 system supports:
● Up to 12 x 3.5-inch SAS/SATA HDD drives
● Up to 8 x 3.5-inch SAS/SATA HDD drives
● Up to 8 x 3.5-inch SAS/ SATA HDD + 8 x 2.5-inch NVMe SSD drives
● Up to 8 x 2.5-inch SAS/SATA HDD drives
● Up to 16 x 2.5-inch SAS/SATA HDD drives
● Up to 24 x 2.5-inch SAS/SATA HDD drives
NOTE: For more information about how to hot swap NVMe PCIe SSD U.2 device, see the D
ell Express Flash NVMe PCIe
SSD User's Guide at https://www.dell.com/support >Browse all Products > Data Center Infrastructure > Storage
Adapters & Controllers > Dell PowerEdge Express Flash NVMe PCIe SSD > Documentation > Manuals and
Documents.