EasyManua.ls Logo

Dell PowerEdge T560 - Environmental Specifications

Dell PowerEdge T560
259 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 20. Supported video resolution options
Resolution Refresh rate (Hz) Color depth (bits)
1024 x 768 60 8, 16, 32
1280 x 800 60 8, 16, 32
1280 x 1024 60 8, 16, 32
1360 x 768 60 8, 16, 32
1440 x 900 60 8, 16, 32
1600 x 900 60 8, 16, 32
1600 x 1200 60 8, 16, 32
1680 x 1050 60 8, 16, 32
1920 x 1080 60 8, 16, 32
1920 x 1200 60 8, 16, 32
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the P
roduct Environmental Datasheet located
with the Documentation on www.dell.com/support/home.
Table 21. Continuous Operation Specifications for ASHRAE A2
Description Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
29
53 ft)
1035°C (5095°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (33.8°F/984 Ft) above
900 m (2953 Ft)
Table 22. Continuous Operation Specifications for ASHRAE A3
Description Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
2
9
53 ft)
540°C (41104°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/175 m (33.8°F/574 Ft) above
900 m (2953 Ft)
Table 23. Continuous Operation Specifications for ASHRAE A4
Description Allowable continuous operations
Temperature range for altitudes <= 900 m (<=
29
53 ft)
545°C (41113°F) with no direct sunlight on the equipment
Humidity percent range (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above
900 m (2953 Ft)
40 Technical specifications

Table of Contents

Related product manuals