PowerVault (Dell MD1400) Setup Guide
High-Level Procedure
This table summarizes the two PowerVaults and two 15-Drive DAC external storage
deployment scenario.
NetWitness Platform 11.3 and Later
Deployment Scenario Tasks
Archiver, Decoder, and
Log Decoder (two Power-
Vaults and two 15-Drive
DACs)
1. Connect the PowerVaults and 15-Drive DACs to the host
before powering on the host as described in Connect
External Storage Devices to an Archiver, Decoder, or Log
Decoder Host.
2. Follow the instructions in the Storage Guide for RSA
NetWitness Platform Version 11.3 and Later to allocate
storage for your hardware.
NetWitness Platform 11.2 and Earlier
Deployment Scen-
ario
Tasks
Archiver, Decoder, and
Log Decoder (two
PowerVaults and two
15-Drive DACs)
1. Connect the PowerVaults and 15-Drive DACs to the host before
powering on the host as described in Connect External Storage
Devices to an Archiver, Decoder, or Log Decoder Host.
2. Run the NwArrayConfig.py script as described in Run the
External Storage Installation Scripts on the Decoder, Log
Decoder, or Archiver.
3. Restart the service as described in Restart the Service.
4. License the host's services (if not already licensed). Refer to the
Licensing Guide available through the application Help option
and RSA Link at https://community.rsa.com/docs/DOC-40370 for
instructions on licensing RSA hosts.
43 Install PowerVaults and 15-Drive DACs on a Series 5 or Series 6 Host (Mixed