10 SCG1000 Force10 S4810 Configuration Guide
FTOS(conf-if-range-fo-0/48-52)#no ip address
FTOS(conf-if-range-fo-0/48-52)#mtu 12000
FTOS(conf-if-range-te-0/48-52)#no shutdown
FTOS(conf-if-range-fo-0/48-52)#flowcontrol rx on tx off
FTOS(conf-if-range-fo-0/48-52)#port-channel-protocol lacp
FTOS(conf-if-range-fo-0/48-52-lacp)#port-channel 1 mode active
FTOS(conf-if-range-fo-0/48-52-lacp)#exit
FTOS(conf-if-range-fo-0/48-52)#exit
FTOS(conf)#exit
2.11 Save configuration
FTOS#copy run start
2.12 Configure additional switch
Repeat the commands from section 2 to configure the second switch.