9 SCG1000 Force10 S4810 Configuration Guide
Option 2: You can enable all ports at once.
FTOS#configure
FTOS(conf)#interface range tengigabitethernet 0/0 47
FTOS(conf -if-range-te-0/0-47)#switchport
FTOS(conf -if-range-te-0/0-47)#no shutdown
FTOS(conf -if-range-te-0/0-47)#exit
FTOS(conf)#exit
2.8 Spanning tree
Manually configure spanning tree if the iSCSI optimization feature is not being used.
FTOS#configure
FTOS(conf)#interface range tengigabitethernet 0/0 - 47
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#exit
2.9 Configure port channel for LAG
These commands configure the switch interconnect as a LAG.
FTOS#configure
FTOS(conf)#interface Port-channel 1
FTOS(conf-if-po-1)#no ip address
FTOS(conf-if-po-1)#mtu 12000
FTOS(conf-if-po-1)#switchport
FTOS(conf-if-po-1)#no shutdown
FTOS(conf-if-po-1)#exit
2.10 Configure QSFP ports for LAG
FTOS(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52

Other manuals for Dell S4810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4810 and is the answer not in the manual?

Dell S4810 Specifications

General IconGeneral
Ports48 x 10GbE SFP+
Uplink Ports4 x 40GbE QSFP+
Switching Capacity1.28 Tbps
Rack Units1U
Product TypeSwitch
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyYes
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Power SupplyDual, hot-swappable
MAC Address Table Size128, 000 entries
Routing ProtocolOSPF, BGP, RIP, PIM, VRRP
Remote Management ProtocolSNMP
FeaturesVLAN, QoS
Humidity10% to 90% non-condensing
Dimensions (WxDxH)43.9 x 46.5 x 4.3 cm

Related product manuals