EasyManuals Logo

Dell S4810 Configuration Guide

Dell S4810
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12 SCG1000 Force10 S4810 Configuration Guide
FTOS(conf-pg)#priority-list 4
FTOS(conf-pg)#set-pgid 1
FTOS(conf-pg)#exit
FTOS(conf)#priority-group OTHER
FTOS(conf-pg)#priority-list 0-3,5-7
FTOS(conf-pg)#set-pgid 2
FTOS(conf-pg)#exit
FTOS(conf)#dcb-output ets
FTOS(conf-dcb-out)#priority-group iSCSI qos-policy iSCSI
FTOS(conf-dcb-out)#priority-group OTHER qos-policy OTHER
FTOS(conf-dcb-out)#exit
FTOS (conf)#service-class dynamic dot1p
3.5 Apply policies to switch ports
FTOS(conf)#interface range ten 0/0 47
FTOS(conf-if-range-te-0/0-47)#dcb-policy input pfc
FTOS(conf-if-range-te-0/0-47)#dcb-policy output ets
FTOS(conf-if-range-te-0/0-47)#protocol lldp
FTOS(conf-if-range-te-0/0-47-lldp)#exit
FTOS(conf-if-range-te-0/0-47)#exit
FTOS(conf)#interface range fortyGigE 0/48 - 60
FTOS(conf-if-range-fo-0/48-60)#dcb-policy input pfc
FTOS(conf-if-range-fo-0/48-60)#dcb-policy output ets
FTOS(conf-if-range-fo-0/48-60)#exit

Other manuals for Dell S4810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4810 and is the answer not in the manual?

Dell S4810 Specifications

General IconGeneral
Ports48 x 10GbE SFP+
Uplink Ports4 x 40GbE QSFP+
Switching Capacity1.28 Tbps
Rack Units1U
Product TypeSwitch
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyYes
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Power SupplyDual, hot-swappable
MAC Address Table Size128, 000 entries
Routing ProtocolOSPF, BGP, RIP, PIM, VRRP
Remote Management ProtocolSNMP
FeaturesVLAN, QoS
Humidity10% to 90% non-condensing
Dimensions (WxDxH)43.9 x 46.5 x 4.3 cm