NOTE: The controller IPv4 addresses and management IPv4 address must be within the same
subnet.
4. Enter the subnet mask of the management network in the Subnet Mask field.
5. Enter the gateway address of the management network in the Gateway IPv4 Address field.
6. Enter the domain name of the management network in the Domain Name field.
7. Enter the DNS server addresses of the management network in the DNS Server and Secondary DNS
Server fields.
8. Click Next. The Set Administration Information page appears.
Set Administrator Information
The Set Administrator Information page allows you to set a new password and an email address for the
Admin user.
1. Enter a new password for the default Storage Center administrator user in the New Admin Password
and Confirm Password fields.
2. Enter the email address of the default Storage Center administrator user in the Admin Email Address
field.
3. Click Next.
For a Fibre Channel or SAS storage system, the Confirm Configuration page appears.
For an iSCSI storage system, the Configure iSCSI Fault Domains page appears.
Configure iSCSI Fault Domains
For a Storage Center with iSCSI front-end ports, use the Configure iSCSI Fault Domains page and the
Fault Domain pages to enter network information for the fault domains and ports.
1. (Optional) On the Configure iSCSI Fault Domains page, click More information about fault domains
or How to set up an iSCSI network to learn more about these topics.
2. Click Next.
NOTE: If any iSCSI ports are down, a dialog box appears that allows you to unconfigure these
ports. Unconfiguring the down iSCSI ports will prevent unnecessary alerts.
3. On the Configure iSCSI HBA Fault Domain 1 page, enter network information for the fault domain
and its ports.
NOTE: Make sure that all the IP addresses for iSCSI Fault Domain 1 are in the same subnet.
4. Click Next.
5. On the Configure iSCSI HBA Fault Domain 2 page, enter network information for the fault domain
and its ports. Then click Next.
NOTE: Make sure that all the IP addresses for iSCSI Fault Domain 2 are in the same subnet.
6. Click Next.
Confirm the Storage Center Configuration
Make sure that the configuration information shown on the Confirm Configuration page is correct before
continuing.
1. Verify that the Storage Center settings are correct.
82
Discover and Configure the Storage Center

Table of Contents

Other manuals for Dell Storage Center SCv2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Storage Center SCv2000 and is the answer not in the manual?

Dell Storage Center SCv2000 Specifications

General IconGeneral
BrandDell
ModelStorage Center SCv2000
CategoryStorage
LanguageEnglish

Related product manuals