THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.

Table of Contents

Questions and Answers

  • J
    Joseph MckayAug 11, 2025
    What to do if Delphi YDT262 shows 'ZERO ANGLE ERROR' message?
    • A
      anna17Aug 11, 2025
      If the 'ZERO ANGLE ERROR' message appears on your Delphi Controller, it means the pump drive shaft was not stationary when the unit was powered on. Ensure the pump is stationary when powering on the unit. If the problem persists, switch the controller off, wait a few seconds, and then switch it back on.
  • C
    Courtney LopezAug 19, 2025
    What to do if Delphi YDT262 Controller powers up, but unexpected messages/characters appear?
    • B
      Benjamin SmithSep 12, 2025
      If your Delphi Controller powers up but displays unexpected messages or characters, switch it off, wait a few seconds, and then switch it back on.
  • M
    mwilsonAug 27, 2025
    Why is my Delphi Controller YDT262 not powering up?
    • A
      Adam SimsAug 27, 2025
      If your Delphi Controller YDT262 is not powering up, check the electrical supply. Also, verify that the 120/240V selector switch is correctly set for your local power supply. Finally, inspect the 3 fuses.
  • R
    rhonda40Sep 2, 2025
    How to fix unstable variation screen on Delphi Controller or when it shows 0 degrees?
    • C
      Christopher RussellSep 2, 2025
      If the variation screen on your Delphi Controller shows 0 degrees or is not stable at 360 degrees, check that the encoder is securely connected. Also, check that the piezo sensor and cable are securely connected. If the issue continues, switch the controller off, wait a few seconds, and then switch it back on.