Chapter 8  Parameters  ASDA-A2 
8-38     Revision February, 2017 
to set the filter timing for the monitoring variable. The value of 
monitoring variable will output after the filtering time determined by 
parameter P0-53. 
For example: when P0-09 is used 
   
 
P0-54    ZON1L 
General Range Compare Digital Output –
Lower Limit of 1st Monitoring Variable 
Address: 006CH 
006DH 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
-2147483648 ~ +2147483647 
 
Data Size: 
32-bit 
 
Format: 
Decimal 
Settings:The value of parameter P0-09 will change within the range between P0-
54 and P0-55 and then output after the filtering time determined by 
parameter P0-53. 
 
P0-55    ZON1H 
General Range Compare Digital Output –
Upper Limit of 1st Monitoring Variable 
Address: 006EH 
006FH 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0 
 
Control 
Mode: 
ALL 
 
Unit: 
- 
 
Range: 
-2147483648 ~ +2147483647 
 
Data Size: 
32-bit