ASDA-A2  Chapter 8  Parameters 
Revision February, 2017    8-137 
P3-01    BRT  Transmission Speed 
Address: 0302H 
0303H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section:  
9.2 
 
Default: 
0x0203 
 
Control 
Mode: 
ALL 
 
Unit: 
bps 
 
Range: 
0x0000 ~ 0x0405 
 
Data Size: 
16-bit 
 
Format: 
Hexadecimal 
 
Settings: 
The setting of transmission speed is divided into Z, Y, X (hexadecimal): 
  U  Z   Y  X 
Communication 
Port 
DMC  CAN / DMC 
- 
RS-232/485 
Range  0 / 3  0~4  0  0~5 
 
 
   Definition of X setting value 
0: 4800  
1: 9600  
2: 19200 
3: 38400 
4: 57600 
5: 115200 
 
   Definition of Z setting value 
0: 125 Kbit/s  
1: 250 Kbit/s  
2: 500 Kbit/s  
3: 750 Kbit/s 
4: 1.0 Mbit/s 
 
   Definition of Z setting value 
0: Use Delta’s controller, such as PLC and HMI 
3: Use Delta’s motion card 
NOTE
 
1)If this parameter is set via CAN, only Z can be set and the others 
remain. 
2)The communication speed of USB is 1.0 Mbit/s only and is 
unchangeable.