Chapter 12 Absolute System   ASDA-A2 
Revision February, 2017     12-25 
AL.289 (PUU), AL.062 (pulse). 
Bit 3 ~ Bit 15: Reserved. Must be set to 0.
 
 
P2-71■ 
 
CAP  Absolute Position Homing 
Address: 028EH 
028FH 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0x0 
 
Control 
Mode: 
ALL 
 
Unit: 
N/A 
 
Range: 
0x0 ~ 0x1 
 
Data Size: 
16-bit 
 
Format: 
Hexadecimal 
Settings: When P2-71 is set to 1, the current position will be set as home position. 
This function is the same as the digital input, ABSC. This function can 
be enabled only when parameter P2-08 is set to 271. 
 
P0-49■ 
 
UAP  Renew Encoder Absolute Position 
Address: 0062H 
0063H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: N/A 
 
 
Default: 
0x0 
 
Control 
Mode: 
ALL 
 
Unit: 
N/A 
 
Range: 
0x00 ~ 0x02 
 
Data Size: 
16-bit 
 
Format: 
Hexadecimal 
Settings:This parameter is used to renew the absolute position data of the 
encoder. 
 
Parameter Renew Setting: 
1: Renew the encoder data to parameters P0-50~P0-52 only. 
2: Renew the parameters P0-50~P0-52, and clear the position error as