Chapter 8 Parameters ASDA-A2
8-14 Revision February, 2017
Alarm of Servo Drive
001:Over current
002:Over voltage
003:Under voltage (In default setting, the alarm occurs only when the
voltage is not enough in Servo ON status; In Servo ON status,
when it applies to power R, S, T, the alarm still will not be cleared.
Please refer to P2-66.)
004:Motor combination error (The drive corresponds to the wrong
motor)
005:Regeneration error
006:Over load
007:Over speed
008:Abnormal pulse command
009:Excessive deviation of position command
010:Reserved
011:Encoder error (The servo drive cannot connect to the encoder
because of disconnection or abnormal wiring)
012:Adjustment error
013:Emergency stop
014:Reverse limit error
015:Forward limit error
016:IGBT overheat

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat