ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-73
Range:
20 ~ 320000
Data Size:
32-bit
Format:
Decimal
Settings:
The number of single-phase pulse output per revolution.
NOTE
The following circumstances might exceed the max. allowable input
pulse frequency and occurs AL018:
1. Abnormal encoder
2. The motor speed is faster than the setting of P1-76.
3.
6
1019.8 4 461P
60
Speed Motor

P1-47 SPOK
Speed Reached (DO:SP_OK) Range
Address: 015EH
015FH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
10 100
Control
Mode:
S / Sz S / Sz
Unit:
r/min 0.1 r/min
Range:
0 ~ 300 0 ~ 3000
Data Size:
16-bit 16-bit
Format:
Decimal Decimal
Settings:
When the deviation between speed command and motor feedback
speed is smaller than this parameter, then the digital output
DO.SP_OK (DO code is 0x19) is ON.
Block diagram:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-A2 Series and is the answer not in the manual?

Delta ASD-A2 Series Specifications

General IconGeneral
Control ModePosition, Speed, Torque
FeedbackIncremental encoder, Absolute encoder
Rated Output Power0.1 kW to 15 kW
Power Supply200-230V AC
Communication InterfaceRS-485, CANopen
Protection FeaturesOverload, Overvoltage, Overcurrent, Overheat